Collision Cell Multi-Collector ICP-MS Sapphire

Price:

0 ₫

Multi-Collector ICP-MS Plasma 3
Multi-Collector ICP-MS Plasma 3
High Resolution Multi-Collector ICP-MS Plasma 1700
High Resolution Multi-Collector ICP-MS Plasma 1700

Collision Cell Multi-Collector ICP-MS Sapphire

Sapphire is a Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) system featuring a proprietary dual-path technology, integrating a collision/reaction cell to thoroughly eliminate spectral interferences from the argon source. The instrument possesses two distinct ion paths: a high-energy path (6 kV) for traditional isotope analyses, and a low-energy path (4 kV) routed through the reaction hexapole. It stands as an ideal solution for analyses in geochemistry, cosmochemistry, and life sciences

7 people are viewing this right now
0 ₫ 0 ₫

  • Field of Study
  • Brand - Nu Instruments
  • Sample materials
Nu Instruments
Nu Instruments

Leading the world in isotope analysis with devices such as MC-ICPMS, TIMS, IRMS, Noble Gas....

Main features


  • Proprietary Dual Path Transfer Optics – two separate ion pathways, allowing flexible switching between MC-ICP-MS mode and collision/reaction cell mode without affecting performance
  • Advanced hexapole Collision/Reaction Cell – up to 4 independently controlled reaction gas inlets (H₂, He, …), removing Ar⁺ signals by more than 9 orders of magnitude, ensuring sensitivity for the analyzed ions
  • Ultra-wide dynamic range multi-channel detector – 16 Faraday cups, up to 6 ion counting detectors (SEM/Daly), dynamic range of 0–75 Gcps (0–1200 V), suitable for trace analysis to high concentrations
  • Outstanding sensitivity with enhanced interface – the highest sensitivity in its class, maintaining optimal ion transmission when switching to cell mode, significantly reducing sample size requirements
  • Variable Zoom Optics and multiple resolution levels – instantaneous switching between isotopic systems during analysis; resolution LR≥1100, MR≥6000, HR≥8000 (10% valley)
  • Wide application and high customization – compatible with wet plasma, membrane desolvation (Aridus3), hydride/cold vapor generation, and laser ablation, suitable for geochemistry, environmental, nuclear, biomedical, and planetary science

Detailed description


Technology & principles

Sapphire is an MC-ICP-MS with two ion pathways in the same machine: (1) high-energy pathway (not through a cell) for isotopes without interference; (2) low-energy pathway through a collision/reaction cell (H₂, He) to eliminate interference (Ar⁺, ArH⁺, ArO⁺). The device has a double-focusing configuration (25 cm magnetic field, 35 cm electric field) ensuring high resolution and stability.

Common limitations of ICP-MS:

  • Traditional high-resolution reduces ion transmission, making it difficult to handle diverse samples (Sr, Nd, Hf, Pb without interference; K, Ca, Fe, Mg with interference).

Advantages of the Sapphire system:

  • Solution: proprietary dual path technology – flexible switching between two modes, eliminating interference at low-resolution, maintaining sensitivity, reducing sample size, optimizing investment costs.

Integration & expansion

  • Supports wet plasma, membrane desolvation, hydride/cold vapor, laser ablation.
  • Automatic sample loading ASX-112FR, soft Faraday switch amplifier, dry pump reduces hydrocarbon background.
  • Sapphire XD variant: Double Wien mass filter + Xtra Dispersion for MS/MS and extended resolution.

Detailed specifications


Parameter

Value

Geometry

Double-focusing (25 cm magnetic field, 35 cm electric field)

Mass range

1 – 300 amu (from Li to U)

Multi-collector

16 Faraday cups (standard), can optionally have 6 ion counting detectors (SEM / Daly)

Dynamic range

0 – 75 Gcps (0 – 1200 V)

Collision/Reaction Cell

Hexapole RF; 4 independently controlled reaction gas ports

Zoom Optics

Variable Zoom, instant switching between isotopic systems

Advanced options

High abundance deceleration filters, Sapphire XD (Double Wien mass filter, Xtra Dispersion collector)

Vacuum system

Fully dry pumped (bơm khô hoàn toàn)

Cooling

Recirculating water system, thermal stability

Field of Study Earth Sciences
Brand Nu Instruments
Sample materials Minerals & Environment
sapphire_nu_instruments_brochure.pdf
Download
Collision Cell Multi-Collector ICP-MS Sapphire
Collision Cell Multi-Collector ICP-MS Sapphire
0 ₫