Multi-Collector ICP-MS Plasma 3

Price:

0 ₫

Enhanced Sensitivity High Resolution ICP-MS Attom ES
Enhanced Sensitivity High Resolution ICP-MS Attom ES
Collision Cell Multi-Collector ICP-MS Sapphire
Collision Cell Multi-Collector ICP-MS Sapphire

Multi-Collector ICP-MS Plasma 3

Plasma 3 is a multi-collector mass spectrometry system specialized for multi-isotope analysis with high accuracy and repeatability. The device features a variable Zoom lens that allows switching between isotope systems without moving the detector. It has a static detector array with 16 Faraday cups and up to 6 ion counting detectors. It is the optimal solution for Earth science, environmental, nuclear, archaeological, forensic, and biomedical applications.

3 people are viewing this right now
0 ₫ 0 ₫

  • Field of Study
  • Brand - Nu Instruments
  • Sample materials
Nu Instruments
Nu Instruments

Leading the world in isotope analysis with devices such as MC-ICPMS, TIMS, IRMS, Noble Gas....

Tags

Main features


  • Exclusive zoom lens – a variable converging lens that allows instantaneous switching between isotope systems (Li → U, Pu) without moving the physical detector.
  • Static multi-channel detector array – 16 Faraday cups and up to 6 ion counting detectors, allowing simultaneous detection of up to 22 ion beams in a mass range of ~15%.
  • Extremely high accuracy and repeatability – relative standard deviation (RSD) for Nd isotope below 0.032% in 7 hours, detection limit below ppq for trace isotopes.
  • Flexible customization according to application – customizable preamp resistance for each Faraday cup, configuration of 0–6 Daly detectors, EATO for Actini applications.
  • Outstanding sensitivity – dry plasma sensitivity: U up to 410 V/ppm, Pb up to 500 V/ppm; wet plasma: U 40 V/ppm, Pb 50 V/ppm. Suitable for ultra-low concentration analysis.
  • Diverse sample source integration – compatible with laser ablation for solid sample analysis, Aridus desolvator, autosampler, GC coupling, and cold gas system.

Detailed description


Technology & principles

Plasma 3 is a multi-collector mass spectrometry system using two sectors for electromagnetic analysis. After ionizing the sample, the ions are accelerated, separated by energy through a static electric field, and then by mass through a magnetic field. The zoom lens technology allows for adjusting the distance between the mass peaks to fit the fixed position of the detector array, facilitating the transition between isotopic systems without the need to move the physical detector.

Hạn chế của ICP-MS thông thường:

  • Traditional MC-ICP-MS often requires moving the detector when switching measurement systems.
  • Trace isotope analysis or elements with ultra-low concentrations (sub-ppq) require very high sensitivity and dynamic range.

Advantages of the Nu Plasma 3 system:

  • Configuration of up to 6 Daly detectors helps expand the dynamic range to >10¹², achieving detection limits below ppq.
  • The EATO option helps improve abundance sensitivity suitable for analyzing complex sample backgrounds.

Integration & expansion

  • The system is compatible with multiple sample sources: laser ablation for solid sample analysis and mapping; Aridus II desolvator for dry sample analysis; ASX-112FR autosampler for liquid sample series; GC for speciation; cold vapor system for Hg and volatile elements.
  • The Plasma 3D variant is equipped with 6 detectors, ideal for lead, U-Pb, Th, and Li isotope analysis.

Detailed specifications


Parameter

Value

Mass range

3 – 300 amu (from Li to U, elements of the Actinide group)

Detector array

16 Faraday cups + up to 6 ion counting detectors (Daly/SEM)

Number of simultaneous detection channels

Up to 22 ion beams in a mass range of ~15%

Signal stability

<0.05 ppm RSD with EATO and deceleration filters

Dynamic range

>10¹² (with enhanced collector and amplifier configuration)

Detection limit

Below ppq (sub-ppq) for trace isotopes

ICP source

New optimized ICP source, high durability and stability

Enhanced options

EATO (Enhanced Abundance Transfer Optics) for application Actini

Vacuum system

Fully turbo pump, additional rotary pump for plasma and interface

Field of Study Earth Sciences
Brand Nu Instruments
Sample materials Minerals & Environment
plasma3_nu_instruments.pdf
Download