Vitesse is an Inductively Coupled Plasma Time-of-Flight Mass Spectrometry (ICP-TOF-MS) system, specifically designed for high-speed multi-element applications such as laser ablation imaging and nanoparticle analysis. It features a segmented reaction cell and powerful interference removal capabilities, making it an ideal solution for geochemical, biological, environmental, and materials research.

10 people are viewing this right now
0 ₫ 0 ₫

  • Field of Study
  • Brand - Nu Instruments
  • Sample materials
Nu Instruments
Nu Instruments

Leading the world in isotope analysis with devices such as MC-ICPMS, TIMS, IRMS, Noble Gas....

Key features


  • Record-breaking acquisition speed – continuous mass spectrum acquisition at 33 kHz – 200 kHz, allowing for the capture of the entire mass range at the fastest speed without interruption.
  • Megapixel resolution imaging – combined with a high-speed laser system, Vitesse allows for the creation of elemental distribution maps over cm² with micron resolution in just a few minutes.
  • High sensitivity on complex sample backgrounds – superior sensitivity allows for probing micron-sized elemental traces in solid samples and determining the elemental composition of individual nanoparticles.
  • Segmented reaction cell – cell specially optimized for multi-element analysis, with multiple gas reaction ports, effectively eliminating spectral interferences such as Ar, Kr, Rb.
  • Flexible Quad-Cell-TOF (QCT) option – an optional full-size quadrupole added before the reaction cell enhances the ability to handle difficult interferences, providing optimal flexibility.
  • 10-order dynamic range and diverse analytical capabilities – combines a proprietary ion beam attenuation system (Physical Beam Attenuator), allowing for the analysis of both ultra-low and high concentration samples on the same sample background.
  • Integrated powerful Nu Quant software – data processing for single-particle, imaging, flow cytometry modes, minimizing processing time.

Detailed description


Technology & principles

Vitesse is an ICP-MS that uses a Time-of-Flight analyzer instead of the traditional quadrupole. Ions are accelerated, flying in the flight chamber, with the time of flight proportional to the square root of m/z → recording the entire spectrum simultaneously after each pulse. The collection speed is hundreds of times faster than sequential mass-filtering ICP-MS, particularly suitable for transient signals from laser ablation, single-particle.

Common limitations of ICP-MS:

  • Traditional ICP-MS (QMS, HR) measures sequentially, unable to record the entire spectrum for short signals (nano-particles, laser pulses). When imaging, thousands of pixels are needed, each point only a few tens of ms → not fast enough. spICP-MS (single-particle) measures only one element at a time, ignoring multi-element correlation.

Ưu điểm của hệ thống Vitesse

  • TOF records the entire spectrum from 7–240 amu simultaneously, with a reading rate of up to 200 kHz, superior time resolution.
  • A rate of 33 kHz creates a megapixel elemental map, providing detailed elemental distribution.
  • spICP-MS simultaneously records all elements in a nanoparticle, determining multi-element composition and correlation.
  • Imaging achieves millions of pixels, increasing spatial resolution without extending time.

Integration & Expansion

  • Compatible with laser ablation (LA-ICP-TOF-MS) from Elemental Scientific Lasers, Applied Spectra.

  • Combines flow cytometry for single-cell, simultaneously measuring metal markers and endogenous elements (Fe, Ca, P).

  • Automatic sample loading option for high throughput solutions.

  • Supports hydride/cold vapor source, GC.

  • Nu Quant software for specialized data processing.

Detailed specifications


Parameter

Value

Mass range

7 – 240 amu (covering most metal and non-metal elements)

Minimum reading time

30 μs

Dynamic range

Up to 10 orders of magnitude

Reaction cell

Segmented reaction cell (segmented)

QCT option (Quad-Cell-TOF)

Yes (full-size quadrupole before cell)

Detector

MagneTOF detector

Interference removal capability

Removal of interference from Ar, Kr, Rb, etc.

Single-particle analysis

Yes, simultaneous multi-element detection

Imaging

Megapixel imaging, speed up to 1000 pixels/second

Field of Study Materials Sciences or Earth Sciences or Life Sciences or Solar & Lithium Batteries
Sample materials Minerals & Environment or Biomedical & Pharmaceutical
Brand Nu Instruments